Q800 Resolution Target
Standardized spatial resolution reference target with positive fluorescence contrast for characterizing imaging spatial resolution and depth of field. Includes electronic Certificate of Verification (.PDF).
Fluorophore: Q800-01 (Peak Ex/Em: 775/787 nm)
Suitable for systems optimized for 800 nm channel fluorophores (pafolacianine, OTL38, IRDye® 800CW)
Reference Target: 1951 USAF Resolution Target - Negative Contrast Mask
- Group 0 through Group 7 feature sizes
- >228 lpmm || > 2.19 µm line spacing
Fluorophore Material: Q800-01 = 600 nM
Optical Properties measured at 𝛌 = 800 nm
- Absorption: µₐ = 0.04 mm⁻¹
- Reduced scattering µ′ₛ = 1.2 mm⁻¹
Dimensions:
- 25 x 25 x 20 mm
Compatible with our open-source QUEL-QAL image analysis library.
Target Mask: Negative 1951 USAF Resolution Target
- Chrome-on-glass, reflective contrast mask
- AR-coated for NIR illumination
- Group 0 through 7 contrast features
- Minimum feature size: 228 lpmm || 2.19 µm line spacing
Fluorophore: 600 nM Q800-01 (Peak Ex/Em: 775/787 nm)
Suitable for systems optimized for 800 nm channel fluorophores (pafolacianine, OTL38, IRDye® 800CW)
Optical Properties
- Absorption (µₐ) = 0.04 mm⁻¹ at 800 nm
- Reduced scattering (µ′ₛ) = 1.2 mm⁻¹ at 800 nm
Dimensions:
- 25x25x20 mm
Our fluorescence spatial resolution targets align with the FDA Draft Guidance and AAPM TG311 Report on standardizing benchmarks for fluorescence surgical imaging system performance.
The spatial resolution target provides positive fluorescence contrast to benchmark fluorescence imaging system performance with a standardized 1951 USAF resolution target mask atop fluorescent Q800 backing material. This target is helpful for:
- characterize fluorescence lateral spatial resolution
- empirically characterizing fluorescence imaging depth of field
- compare predicate device imaging performance for equivalence justification (e.g., 510(k) submission)
We provide a getting started guide, directions for use, and practical tutorials on using fluorescence spatial resolution targets for your application.
Our open-source QUEL-QAL python library helps you generate standardized performance reports from raw image data, enabling consistent benchmarking across development cycles and facilitating objective system-to-system comparisons. Video tutorials for using QUEL-QAL can be found in this playlist on our YouTube page.
To help maintain the performance and longevity of the fluorescent reference targets, we recommend minimizing prolonged light exposure. For absolute radiometric benchmarking of system performance, we recommend using the RET target.