Quantitative Q700 Reference Set
Absolute fluorescence performance characterization against an included calibrated radiometric reference standard.
Reference set includes:
- Q700 Concentration Sensitivity Target
- Q700 Depth Sensitivity Target
- Q700 Resolution Target
- 720 nm Radiometric Target with Power Supply
- Electronic Certificate of Verification (.PDF) and Calibration File (.XLS)
Sizes:
- Standard: 50 x 50 x 20 mm
- Mini: 25 x 25 x 20 mm
Fluorophore: Q700-01 (Peak Ex/Em: 695/705 nm)
Suitable for systems optimized for 700 nm channel fluorophores (Cy5.5, SGM-101)
Compatible with our open-source QUEL-QAL image analysis library.
Fluorophore: Q700-01 (Peak Ex/Em: 695/705 nm)
Suitable for systems optimized for 700 nm channel fluorophores (Cy5.5, SGM-101)
Q700 Concentration Sensitivity Target
Fluorescent Features:
- [1, 3, 10, 30, 60, 100, 300, 1000] nM of Q700-01
- 1 negative control well (0 nM)
Base optical properties:
- Absorption (µₐ) = 0.03 mm⁻¹ at 800nm
- Reduced scattering (µ′ₛ) = 0.4 mm⁻¹ at 800nm
Dimensions:
- (Standard): 50x50x20mm | ⦰10mm feature size
- (Mini): 25x25x20mm | ⦰5mm feature size
Q700 Depth Sensitivity Target
Optical Properties:
Top: 0.5-6mm tissue-equivalent material non-fluorescent material
- Absorption (µₐ) = 0.01 mm⁻¹ at 800 nm
- Reduced scattering (µ′ₛ) = 1.5 mm⁻¹ at 800 nm
Bottom: 8 wells 1000nM Q700-01, 1 negative control well
- Absorption (µₐ) = 0.03 mm⁻¹ at 800 nm
- Reduced scattering (µ′ₛ) = 0.4 mm⁻¹ at 800 nm
Negative control has 6mm of top material
Dimensions:
- (Standard): 50x50x20 mm | ⦰10 mm feature size
- (Mini): 25x25x20 mm | ⦰5 mm feature size
Q700 Resolution Target
Target Mask: Negative 1951 USAF Resolution Target
- Chrome-on-glass, reflective contrast mask
- AR-coated for NIR illumination
- Group 0 through 7 contrast features
- Minimum feature size: 228 lpmm || 2.19 µm line spacing
Fluorophore: Q700-01 (Peak Ex/Em: 695/705 nm)
Suitable for systems optimized for 700 nm channel fluorophores (Cy5.5, SGM-101)
Optical Properties
- Absorption (µₐ) = 0.03 mm⁻¹ at 800 nm
- Reduced scattering (µ′ₛ) = 0.4 mm⁻¹ at 800 nm
Dimensions:
- 25x25x20 mm
720 nm Radiometric Emitter Target (RET)
Optical Output:
- Center Wavelength = 720 nm
- Adjustable radiometric output from ~0.05 - 300 µW/(cm^2 str)
- Mimics Q700 NIR fluorescence spectral emission properties
- Calibration file provided for each unit.
Dimensions:
- 25x25x20mm
Guides & Resources:
Concentration Target Getting Started Guide
Depth Target Getting Started Guide
Resolution Target Getting Started Guide
Radiometric Emitter Target Getting Started Guide
Radiometric Emitter Application Note - Photobleaching Management
Reference Target Directions for Use
FAQs
Technical Drawings
Standard Concentration Sensitivity Target Technical Drawing
Standard Depth Sensitivity Target Technical Drawing
Resolution Target Technical Drawing
RET Technical Drawing
Our Q700 quantitative reference set adds a traceable, calibrated radiometric emitter to our base fluorescence reference set. The emitter provides a stable reference optical signal that is not impacted by illumination conditions, enabling traceable optical characterization across multiple imaging systems for standardized comparison.
A stable, calibrated reference signal lets you turn your quantized image intensities into standardized radiometric units (e.g., mW/cm^2 str). The flexibility of a stable reference signal helps dial in imaging parameters and standardize traceable performance characterization in absolute radiometric units.
Our quantitative fluorescence reference target kit aligns with the FDA Draft Guidance and AAPM TG311 Report on standardizing benchmarks for fluorescence surgical imaging system performance. This kit enables teams to characterize critical system performance metrics including:
- fluorescence sensitivity range
- linear dynamic range
- imaging system noise floor
- fluorescence detection limits
- saturation thresholds
- tissue sensing depth
- fluorescence imaging spatial resolution
- fluorescence lateral spatial resolution
- fluorescence imaging depth of field
- radiometrically standardized performance quantification
Combined with our fluorescence reference targets, the RET provides a fully-traceable, quantitative basis for fluorescence imaging system characterization useful for:
- optimizing image capture parameters
- assessing spectral filtering performance
- predicate device comparisons for equivalency justification (e.g., 510(k) submission)
- establishing Imaging system performance repeatability ahead of production
- system comparisons against a traceable reference standard
- absolute radiometric imaging performance characterization
- managing fluorescence target photobleaching during high-volume use.
All quantitative reference kits include an electronic Certificate of Verification (.PDF). and supporting calibration files (.XLS) for serialized RET targets.
The Quantitative Q700 Reference Set streamlines phantom characterization time while providing reproducible, traceable performance data to support your design verification, validation testing, predicate device equivalency, and regulatory documentation requirements.
Our open-source QUEL-QAL python library helps you generate standardized performance reports from raw image data, enabling consistent benchmarking across development cycles and facilitating objective system-to-system comparisons. Video tutorials for using QUEL-QAL can be found in this playlist on our YouTube page.
To help maintain the performance and longevity of the fluorescent reference targets, we recommend minimizing prolonged light exposure. For absolute radiometric benchmarking of system performance, we recommend using the RET target included in this set.