Base ICG Reference Set
Streamline fluorescence imaging system performance characterization and accelerate device development with the base ICG fluorescence reference set.
Reference set includes:
- ICG Concentration Sensitivity Target
- ICG Depth Sensitivity Target
- ICG Resolution Target
- Electronic certificate of verification (.PDF)
Sizes:
- Standard: 50 x 50 x 20 mm
- Mini: 25 x 25 x 20 mm
Fluorophore: ICG-01 (Peak Ex/Em: 811/822 nm)
Suitable for applications using 820 nm channel fluorophores (e.g., ICG, indocyanine green)
Compatible with our open-source QUEL-QAL image analysis library.
Fluorophore: ICG-01 (Peak Ex/Em: 811/822 nm)
Suitable for applications using 820nm channel fluorophores (e.g., ICG, indocyanine green)
ICG Concentration Sensitivity Target
Fluorescent Features:
- [1, 3, 10, 30, 60, 100, 300, 1000] nM of ICG-01
- 1 negative control well (0 nM)
Base optical properties:
- Absorption (µₐ) = 0.03 mm⁻¹ at 800nm
- Reduced scattering (µ′ₛ) = 0.4 mm⁻¹ at 800nm
Dimensions:
- (Standard): 50x50x20 mm | ⦰10mm feature size
- (Mini): 25x25x20 mm | ⦰5mm feature size
ICG Depth Sensitivity Target
Optical Properties:
Top: 0.5-6 mm tissue-equivalent material non-fluorescent material
- Absorption (µₐ) = 0.01 mm⁻¹ at 800 nm
- Reduced scattering (µ′ₛ) = 1.5 mm⁻¹ at 800 nm
Bottom: 8 wells 1000 nM ICG-01, 1 negative control well (0 nM)
- Absorption (µₐ) = 0.03 mm⁻¹ at 800 nm
- Reduced scattering (µ′ₛ) = 0.4 mm⁻¹ at 800 nm
Negative control has 6mm of top material
Dimensions:
- (Standard): 50x50x20 mm | ⦰10 mm feature size
- (Mini): 25x25x20 mm | ⦰5 mm feature size
ICG Resolution Target
Target Mask: Negative 1951 USAF Resolution Target
- Chrome-on-glass, reflective contrast mask
- AR-coated for NIR illumination
- Group 0 through 7 contrast features
- Minimum feature size: 228 lpmm | 2.19 µm line spacing
Fluorophore: 1000 nM ICG-01 (Peak Ex/Em: 811/822 nm)
Optical Properties
- Absorption (µₐ) = 0.03 mm⁻¹ at 800 nm
- Reduced scattering (µ′ₛ) = 0.4 mm⁻¹ at 800 nm
Dimensions:
- 25x25x20 mm
Guides & Resources:
Concentration Target Getting Started Guide
Depth Target Getting Started Guide
Resolution Target Getting Started Guide
Reference Target Directions for Use
FAQs
Technical Drawings
Standard Concentration Sensitivity Target Technical Drawing
Standard Depth Sensitivity Target Technical Drawing
Resolution Target Technical Drawing
Standardize and accelerate your fluorescence imaging system development with quantifiable performance metrics.
Our base fluorescence reference target kit aligns with the FDA Draft Guidance and AAPM TG311 Report on standardizing benchmarks for fluorescence surgical imaging system performance.
This ICG fluorescence reference set simplifies characterizing 820 nm channel imaging system performance metrics including:
- Fluorescence sensitivity range
- Linear dynamic range
- Imaging system noise floor
- Fluorescence detection limits
- Saturation thresholds
- Tissue sensing depth
- Fluorescence imaging spatial resolution
- Fluorescence lateral spatial resolution
- Fluorescence imaging depth of field
Development teams find the base reference set useful in addressing critical tasks to bring devices to market, such as:
- Optimizing image capture parameters
- Assessing spectral filtering performance
- Comparing predicate devices for equivalency justification (e.g., 510(k) submission)
- Establishing imaging system performance repeatability
Our base reference sets are available with standard (50 x 20 x 20 mm) or mini (25 x 25 x 20 mm) concentration/depth target sizes to best suit your application (e.g., open-field imaging, endoscopic imaging, probe-based sensing).
Our open-source QUEL-QAL python library helps you generate standardized performance reports from raw image data, enabling consistent benchmarking across development cycles and facilitating objective system-to-system comparisons. Video tutorials for using QUEL-QAL can be found in this playlist on our YouTube page.
All base reference kits are serialized and include an electronic Certificate of Verification (.PDF).
To help maintain the performance and longevity of the fluorescent reference targets, we recommend minimizing prolonged light exposure. For absolute radiometric benchmarking of system performance, we recommend using the RET target included in our Quantitative ICG Reference Set.